155 5. Reply Quote. g. Business, Economics, and Finance. . M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by M302 P1 ; allow cold extrude M302 S0 R0 ; allow cold extrude;M563 P1 P3 S"filament" D1 H1 H3 F4 ; define tool 1;G10 P1 X0 Y0 Z0 ; set tool 1 axis offsets;G10 P1 R0 S0 ; set initial tool 1. M302 works fine in a starting script or sent via console. 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Hooray! Again, it's just odd that everything worked with that exact same config in the previous interface. 8. R"Filament out" S2 ; Step 3 > After checking you click okay and it starts reversing filament M302 P1 ; Allow cold extrusion G1 E-520 F3000 ; Unwind the filament 400mm ; Step 4 > Notify user and offer option to place new filament M291 P"Remove remaining filament, insert new filament and continue" R"Insert new filament" S2 G1 E480. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. 1 Reply Last reply Reply Quote 0. 1 Reply Last reply Reply Quote 0. Click to Enlarge. So when i home it, x and y go to 225 and z goes to 0. Tools; M563 P1 S"Clay" D0 ; Define tool 1 M563 P2 S"plastic" D1 H2 ; Define tool 2 G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets Some common uses…. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. Hi all, Can anyone help using DC42 firmware I cannot get the extruder to cold extrude even when using the M302 P[1/0] to enable or disable the prevention. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. g on the SD card (you can do this in the web interface). @2:0 SENT: M302 RECEIVED: ok 0 RECEIVED: Cold extrusion allowed RECEIVED: wait Zum Test verwende ich immer Folgendes: G91 G1 E500 F3000 1-mal bearbeitet. In order to move the extruder, do I need set the temperature control input for the extruder heater? I have setup multiple tools that share a heater and have dedicated extruder drives. Grabbed a Ramps 1. The commands I gave it was: T0 ; just to be sure M302 P1 ; I think it wM302 P1 ; allow cold extrusion. 36°C/sec measured -0. 26" ; configure active-high endstop for low end on Y via pin null M574 Z1 S1 P"!P1. G-Code commands¶@jfavre said in Extruder motor not working. I'm at a dead end where I can't seem to get the E0 Stepper motor to. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. To test for this, with the power off swap the E0 connector on the Duet with another one e. com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. Already have an account? . com], E3D tool changer, Robotdigg SCARA printer, Crane Quad and OrmerodDisclosure: I design Duet electronics and work on RepRapFirmware, []. Only users with topic management privileges can see it. Still no luck with Extrusion Control jogging buttons. g: T0 ; select tool 0. oracledude 5 Dec 2021, 21:47. However, a steps/mm value of 5. Set the temperature (and enable) using. droftarts administrators @flyscha last edited by . After creating these and making all the connections we can move onto updating the firmware. Support and Discussion forum for Duet3D Hardware, Firmware, Software, plugins and wider 3d printing/CNC discussion. EDIT: OK, so you're using RRF 3. I have waisted hours t. 3 ; Filter. 00°C/sec. And now even Col Extrusion M302 P1 is generating errors. M302 P1 ; disable cold extrusion checking And yes each extruder is a tool T0 G1 E20 ; move current extruder 20mm T1 G1 E20 T2 G1 E20 Edited 2 time(s). ; Heaters;M143 H1 S260 ; Maximum heater temperature M140 H-1 ; No bed heater;M305 P1 T100000 B4138 C0 R4700 ; Thermistor parameters for heater 1;M307 H1 A577. 3 ; Cold-Section fan. after turning off cold hotend detection with M302 P1. Last edit at 01/11/2023 01:58AM by Dust. 15mm Nozzle (Pink)The punch slide unit is driven by the punch shift motor (M302). I just wondered if there was a way of "embedding" it in the config files so that it runs by default. . M302 S160 ; lower cold extrusion limit to 160C {if filament_type[initial_tool]=="FLEX"}G1 E-4 F2400 ; retraction{else}G1 E-2 F2400 ; retraction{endif}. Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. Trying to figure out why I can't run my extruder. Re: Extrude without a Hotend May 04, 2017 11:25PM. gcode" and run that from an SD card. 0. what gcode do i need to send… Premium ExploreTo install this plugin, open DWC, go to Settings -> Plugins -> External Plugins and click on "Install Plugin". 5mm/sec echo "Done" M82 ; set extruder to abs modeBusiness, Economics, and Finance. On Duet 3 if I send "M302P1" from the GCode console it returns "Error: Bad command". M302 P1 (This will revert the next time you reset or power off the Duet, or you can send ‘M302 P0’. 0. According to the docs, putting nothing or 0 means infinity. Direct drive: Remove your nozzle, hotend, or extruder. Just need to find settings for Slice Engineering 300c thermistor, the temp reading slightly higher than actual measured with an TC thermometer. Dear all i have 4 heaters, when i try to heat all of them at same time, it automatically goes to standby mode, what will be reason? when i individually heat them it works fine. It will not move when the hotend is cold as a safety feature in the firmware. 7mm, the output contact is engaged @ about 0. This topic has been deleted. There is no minimum steps/mm set in the firmware. M302 works fine in a starting script or sent via console. 5 (2022-11-30 19:41:16) running on Duet 3 Mini5plus WiFi (SBC mode)You need to edit homeall. . 1 Reply Last reply Reply Quote 0. Fan1 configured in thermostatic mode by default. g. 3rd print: Layer shift of 3mm at layer 3 starting somewhere at 30x25. G1 F200 E0. Connector for the extruder is plugged into second connection (i. 0. g file and M302 reporting that cold extrusion is. Re: How can I move E steppers? January 11, 2023 02:36AMJust to bed the gears and drive cable in. @Phaedrux said in Extruder motor not working. I can get the x,y,and z motors moving in pronterface, but the extruder…@jfavre said in Extruder motor not working. The prototype was outsourced to Oshpark. : Just need to find settings for Slice Engineering 300c thermistor, According to this document, you need to use the following in your M308 T100000 B4680 C6. M569 P1 S0 ; physical drive 1 goes forwards using default driver timings M569 P2 S1 ; physical drive 2 goes forwards using default driver timings. Set nozzle and bed temperature to something below 30°C so the hotend fan wont spin up. Repetier 1. It works perfectly fine on RRF2 though. droftarts administrators @flyscha last edited by . See: Promega SupportBusiness, Economics, and Finance. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTP M586 P1 S0 ; Disable FTP M586 P2 S0 ; Disable. yello3d. 1 active and standby temperatures to 0C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C $\begingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. 3. Last edit at 01/11/2023 01:58AM by Dust. [Note: parameter letter E is a special case, an E parameter must always be preceded by a. config. P1: Acute abdominal pain (e. 3 mm and released @ about 0. Thermostatic control is turned off ; Fan for the hotend M950 F1 C"out6" L0:1000 Q50 ; create fan 1 on pin out6 and set its frequency M106 P1 S1 H1 T45 C"Hotend" ; set fan 1 value. 00 and cannot get the stepper motors of the extruders to work. This manual can be used as an EIA/ISO programming manual. It was type 5 in marlin. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. But when i try to run it from DWC, I get the error: G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C M302 P1 ;allows cold extrusion with RepRap, otherwise "M302" alone works T0 ;selects tool0;M563 S1 ;allows for tool nomenclature compatibility between Slic3r and RepRap (Tools 0&1 vs Toos 1&2) I don't even want to do homing yet because my endstops are still screwed up, fortunately for my purposes I don't actually require them to work to get. @jfavre said in Extruder motor not working. 3 ; Filter. M98 Punload . M302 P1 disables the cold extrude safety. Thermostatic control is turned off, Minimum fan value 0. The config changes were correct. M302_P1_COLD_E. G1 E20 moves E0 as expected T1 changes tools as expected G1 E30 move E1 as expected. Expected behavior: The Unload should ignore the temperature on the Hotend and do its. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. 4. com ], E3D tool changer, Robotdigg SCARA printer, Crane Quad and Ormerod. Slic3r 1. If that's not the case, we need to change the direction of rotation. Recently i have been testing the clay extruder connected to the Driver0 on Duet 3 Mainboard 6HC. It has a different internal construction. So currently I've been slowly working my way throw learning Marlin and Visual studio as well as trying to build my 3d printer with the SKR2. M569 P1. Hi I am building a machine that is not a 3D printer but as I have liked a lot Duets for years now I decided to use one as a controller in this project too. After replacing PCB managed to get everything up and running. Not sure what could be wrong in your case as M302 with no parameters should report the current cold extrusion protection settings. I have a setup similar to the ANET A8. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. The SMuFF is supposed to beep for 1 second. 0C. but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?So when i home it, x and y go to 225 and z goes to 0. Only users with topic management privileges can see it. g. (You'll need to pull hard sometimes) Step 7 Printer: Anycubic Chiron, Firmware: Marlin 2. M302 P1 ;allow cold extrusion T0 G1 E1000 F3600 ;new step/mm = old*1000/Measured ;example 1024 measured with old steps = 310 -> new = 310*1000/1024 = 302. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Business, Economics, and Finance. It was type 5 in marlin. Reply Quote. 1 Reply Last reply Reply Quote 0 droftarts administrators @flyscha last edited by G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. The extrude and retract buttons are grayed out when the thermistors aren't connected. M808 L. Other possible causes are a bad stepper motor or cable. g to make the process as painless as possible. Equipped with a remote controller designed for enterprise users and the newly upgraded Pilot 2 flight app, to improve the efficiency of drone operations. But when i try to run it from DWC, I get the error: M302 ; report current cold extrusion state M302 P0 ; enable cold extrusion checking M302 P1 ; disable cold extrusion checking M302 S0 ; always allow extrusion (disable checking) M302 S170 ; only allow extrusion above 170 M302 S170 P1 ; set min extrude temp to 170 but leave disabled M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled: To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. This is the case even with M302 P1 at the bottom of the config. M569 P1 S1 D3 V0 ; Drive 1 goes forwards, CoreXY_2, stealth chop, disable spread cycle M569 P2 S1 D3 V0 ; Drive 2 goes forwards, Z Motor, stealth chop, disable spread cycle. . The extrusion amount of the first layer is extremely low, but the other layers are fine. 455513e-8Ok if the motor is confirmed working, then at least cold extrusion should allow it to extruder as long as the tool is actually selected. I just wondered if there was a way of "embedding" it in the config files so that it runs by default I'll set up a macro instead Thanks guysG-code for the 4th axis of the tangential knife after a slight modification {ASCI "conversion " (" to ";" and "A" to "E") allows you to run the code in the Marlin software. M302 works fine in a starting script or sent via console. G-Code commands¶I do a lot of production and using Pause to change color was always a pain and no use for large productions or non casual prints so this week started to test the idea of using the nice pause. Here is a handy list of g-code commands Reply Quote. For firmware versions 1. . Don't disable the thermal runaway protection. 9 mm of feed stock: G92 E0 ;zero the extruded length again: G1 F900 ; set the feed-rate // Starting the print with Layer 0;Layer count: 1;LAYER:0: M107Preheat the hot end, if desired (or send M302 P1 if you intend to use the macro when the hot end is cold) Use M913 Ennn to reduce the motor current, if necessary (see #1 above) Use M83 to select relative extruder motion, in case the macro is. Heating Bed manually by G-Code. T0, you need to either heat up that tool, or enable cold extrusion by sending M302 P1. M302 by itself displays the current cold extrusion status (RepRapFirmware). g. oracledude 5 Dec 2021, 21:47. Speaking of which. the X motor. 0. @agent0810 said in Homing advice: the z is at 0 at the top, so it cant go lower right? shouldnt it home at 300 something? im having issues moveing the bed. I reduced. Step 6. 042". Other possible causes are a bad stepper motor or cable. Example output if disabled: echo:Cold extrudes are disabled (min temp 170C) Example output if enabled:M581 P1 T2 S0 R0 ;define trigger for filament auto load triggers trigger2. M302 P1 ; Allow Cold extrudes; Thermistors M305 P0 T100000 B3950 R2200 H30 L0 M305 P1 T100000 B3950 R2200 H30 L0 M305 P2 T100000 B3950 R2200 H30 L0. GameStop Moderna Pfizer Johnson & Johnson AstraZeneca Walgreens Best Buy Novavax SpaceX Tesla. Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. Now all the other axis are moving as supposed but the extruder ones are not. I used M302 P1 and it worked fine when I was testing my new extruder stepper motor. Extrude a little more filament: G1 E20 F200; Measure as accurately as you can using a rule between your marks. M302 P0 S170. Ralms @fcwilt 8 Aug 2020, 08:57. First print: tiny layer shift at layer 6. Trying to figure out why I can't run my extruder. CryptoI did try a cold extrude M302 P1. 9 ;extrude 0. However, I can't get the servo running with the new firmware. There is no minimum steps/mm set in the firmware. . When I print using the code below (it is longer, but I do not know where to put attachments), I can see that the extruder-gear is jerking, as if it tries to do tiny retractions between every little movement. the X motor. The M2 Carbine rifle is a fully automatic version of the M1A1. Without inserting the wire I tried to make a print and the extruder works. 8 amps (JK57HS56-2804) with gear boxes for extra power. 0. 2 Firmware:3. : M302 Just got the extruder motor to work with G1 E1 F100 andG1 E-1 F100. g. Crypto3D Printer Chess. plan view. @DjDemonD:. if I'd have sent the extrude G code it probably would've extruded. . Hello. I've now managed to calibrate my Steps/mm of the extruder by manually issuing G1 commands. . @deckingman Replacing the P1 with P0 in the config file was the trick! Now the retract option is available immediately when I activate the hot end heater, and when it reaches 160c, the extrude option is now available. I drive them with: M906 X1000 Y1000 Z1000 E900 I30 One of the steppers starts skipping since some days and I'm unable to find the reason. 7. Re: Help with extruder feed calibration -. the ONLY command that should spin a motor before the printer homes is G28. Re: Extrude without a Hotend. Direct drive: Remove your nozzle,. Make sure you clean out the heatblock and refit the nozzle properly, hot tightening it, etc. X moves almost free, lets say as much as you can tell with the belt installed without the steppers. M302: Allow cold extrudes add cancelling of the command; M561: Set Identity Transform - reset the transformation from calibration; Non specific G-codes Movement. Just enter the above code from your host software (pronterface or repitear) and you should be good to test the paste extruder. ) You can feed filament at 800mm/m (web interface max speed is 240mm/m), at 100mm at a time, until the filament is near the nozzle. Then try to extrude 5mm from Pronterface UI, there’s a button for it under the move. 1 Reply Last reply Reply Quote 0. Extrusion Control in DWC unavailable, even after M302 P1. (You will have to switch off the temperature control as most controllers will not move the extruder stepper unless the hot end it up to temperature) Use M302 P1 on RepRapFirmware to switch cold extrusion on (allow extrusion while cold) and M302 P0 to switch it off again. 16 and earlier, set the B parameter (beta value) to 4388. However, some firmware distributions might explicitly prevent these two commands of turning off the check. 6, no change. All models of the M1 carbine family (including the M2 and M3 carbines) fired a . and Terra makes the best looking meshes by far. g. g. M950 F0 C"fan0" Q500 ; create fan 0 on pin fan0 and set its frequency. M116 P0 ; wait for heating up. 2 ; interpolate mbl probesG29 P3. If that's not the case, we need to change the direction of rotation. Duet 3 mini 5+ installed in a Sidewinder x1 v1. @dc42 That doesn't seem to work. I probed the STEP output with an oscilloscope and the pulses are there and the pulse length is fine. I thought I was having problems outputting STEP and DIR to the G320x, but actually it was a current issue in 3. What could be the causeMarlin defaults to "no cold extrusion". but if i want -z to go down shouldnt 0 be at the bottom? how would i swap that around, change the motor direction like you suggested in your last post?I did try a cold extrude M302 P1. Expected behavior: The Unload should ignore the temperature on the Hotend and do its thing. Here is a handy list of g-code commands [ reprap. @agent0810 said in Homing advice: i was able to. Let me explain better: I need to set the T0 value to 170/25 degrees as dummy to run the right Titan to verify the right amount of filament that extr. 23". ino in the repo. @agent0810 said in Homing advice: but then when i tried to home it sent the bed to the bottom Then we need to change the motor direction for Z like we did for the X and Y. W} F10000 ; grab filament for automatic feed while sensors. Heater 1 fault: temperature rising too slowly: expected 2. CryptoM302 P1 ; enable cold extrusion G4 S1 ; wait for one second G1 E15 F500 ; load filament inside the gears. 36°C/sec measured -0. How would I know to send a T0 and then M302 P1 to test the extruder? Quote dc42 Make sure you have a tool selected (e. G4 S1 ; wait for one second. gpIn[0]. M302. Pix4d often makes vertical surfaces to 45 deg where they meet the ground. Anytime I extrude a certain length of filament, the extruder retracts the same length it seems. G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C G10 P1 X0 Y0 Z0 ; Set tool 1 axis offsets G10 P1 R0 S0 ; Set initial tool 1 active and standby temperatures to 0C M302 S120 R110 ; Allow extrusion starting from 120°C and retractions already from 110°C Sending M302 P1 shows green as though it accepts the command, but the extrude & retract buttons are still grayed out. dc42 administrators @dsela last edited by dc42 . Failure to extrude in RepRapFirmware is usually caused by either cold extrusion prevention (but you have sent M302 P1 to disable that), or not having the tool selected. 2mm. To test for this, with the power off swap the E0 connector on the Duet with another one e. M302 P1 M584 E3:4;M563 P0 D3:4 ; Define tool 0 (no heaters assigned);M567 P0 E1:1;M584 E3:4;M302 P1 ;COLD EXTRUSION ON; Network M550 PXTP1 ; Set machine name M540 PBE:EF:DE:AD:FE:ED ; Set MAC address M552 P0. M302 P1 ; Allow Cold extrudes M98 Pmachine_maxtemp. 12/28/2022, 7:25:14 PM M302 Cold extrusion is allowed (use M302 P0 to forbid it) 12/28/2022, 7:25:05 PM M302 P1 12/28/2022, 7:23:58 PM M302 Cold extrusion is forbidden (use M302 P1 to allow it), min. Send T0 in the gcode console and check the buttons again. retraction temperature 90. After you’re done calibrating Esteps, re-enable cold extrusion temperature checking with M302 P0 As has been mentioned, heating the nozzle also works. Large delta printer [miscsolutions. M302 P1 ; enable cold extrusion M201 E1000 ; reduce extruder acceleration M915 P3 S10 F0 R0 ; set stall detection threshold M913 E100 ; set extruder motor to reduced % current M83 ; relative extrusion G1 S1 E800 F3600 ; move fast 500mm of filament M913 E100 ; set extruder motor to full current M302 P0 ; disable cold extrusion G1 E50 F300. To print at this lower temperature, g-code command M302 P1 was used to disable the printer’s cold extrusion checking. Send T0 before you try to extrude. 3 ; Filter. R"Filament out" S2 ; Step 3 > After checking you click okay and it starts reversing filament M302 P1 ; Allow cold extrusion G1 E-520 F3000 ; Unwind the filament 400mm ; Step 4 > Notify user and offer option to place new filament M291 P"Remove remaining filament, insert new filament and continue" R"Insert new filament" S2 G1 E480 F2000 ; Load. This topic has been deleted. 3V is removed from the E1STOP signal, in which case the log will display the command entered. G-Codes¶. M302 P1; Axis Limits M208 X-50 Y0 Z0 U0 S1 ; set axis minima M208 X210 Y220 U260 Z200 S0 ; set axis maxima ; Endstops M574 X1 S1 P"io0" ; configure switch-type (e. Extrude a small amount to ensure that your extruder motor is on and holding. Only users with topic management privileges can see it. 0 S1 ; Enable network and acquire dynamic address via DHCP M586 P0 S1 ; Enable HTTPThermostatic control is turned on. x) or M557 P1 S0 (FW >3. M302 P1 Now advance the filament using the jog buttons on the Manual Control tab, until it reaches the top of the heatsink. 1 Reply Last reply Reply Quote 0. To test for this, with the power off swap the E0 connector on the Duet with another one e. and forward - so we have are at the point we wanted to be without. wordpress. 0. 06. 00" standard bore "competition" gasket for cast iron or aluminum cylinder heads on 302 and 351W production blocks. This will hopefully make it a bit easier for me to. I used to use "Pronterface" for that. g (typically the Tools section) but write down the configured heater, fan, and extruder numbers mapped to. g at here G91 ; relative positioning G1 Z5 F6000 S2 <--(problem is here, remplace S2 by H2) ; lift Z relative to current position G90. Re: How can I move E steppers? January 11, 2023 02:36AMI used the safety scissors to cut off the fingers of the severed hand then tried to give her the fingers. When I try to run the extruder (for example G1 E1) I make sure to allow cold extrusion (M302 P1). 3 E40 ; set drive mapping. M302 P0. Set the temperature (and. 0. Sending T0 initiates the heater and then faults out. You will have to preheat the hotend first before moving E or you can try sending the M302 P1 Gcode via the terminal in pronterface to allow cold extrusion. When setting my Anet A8 printer at that temp, the extruder motor doesn't turn by…Beat me to it! If the current tool doesn't have any heaters assigned to it, extrusion is allowed always. Last edit at 01/11/2023 01:58AM by Dust. G1 E15 F500 ; load filament insi de the gears. Sometimes it moves once but doesn't execute the other commands. 36°C/sec measured -0. Ok i did the test you asked and did the commands thru the gcode console and with tool 0 on drive 0 selected when i give the G1 E20 F5 command i get a slight twitch on the motor shaft but the shaft spins freely with little to no resistance on the shaft i switched the motor cable to the drive 1 and set my config_g to use tool 0 drive one and with tool 0. 5mm/sec echo "Done" M82 ; set extruder to abs mode 1 Reply Last reply Reply Quote 0There is one extra complication in moving the extruder. droftarts administrators @flyscha last edited by . 1 Reply Last reply Reply Quote 0. I can't move the cold extruder to load the wire. This manual describes the machines of the INTEGREX e-series, INTEGREX i-series, and VORTEX i-series. g macro is;Autoload filament macro. $egingroup$ That fix, sending M302 P1 (the P1 is important) and then M500 can be done in any program that can communicate directly with the printer. The Panasoic Felios F775 conformal metasurface is shown in Figure 9c. Crypto@gloomyandy are these values incorrect?; Tools M563 P0 S"volcano" D0 H1 F0 ; define tool 0 G10 P0 X0 Y0 Z0 ; set tool 0 axis offsetsExtruder SKR2 not spinning. . Duet Web Control makes it easy to upload, edit and create new macros. However, Slic3r inserts this code after the first Z-lift which is befo. Technical Explanation 1. I am at a loss for next step. 2 Y0. g. Other possible causes are a bad stepper motor or cable. send T0), and enable cold extrusion with M302 P1. g underneath: M122 === Diagnostics === RepRapFirmware for Duet 3 Mini 5+ version 3. 2"x12" backing boards 2"x4" studs 16. . @jfavre Are you sure you have a tool selected (with T0, you will need that as well as the M302 P1)? What response did you get to M302 (before and after you set M302 P1)? Have you tried heating the nozzle? 1 Reply Last reply Reply Quote 0. With steps/mm so low you will get nothing like enough torque out of your motor to extrude anything, unless it is a really huge motor. After I have executed the M302 S1 command, the extruder moves a few steps in one direction and then stops. M302 S60 (for M3 and M2 Series printers) M302 P1 for (for Ultra One printers) (this allows the printer to extrude with the hot end above 60 degrees and is only a temporary change). Deactivate with "M106 P1 H-1". CryptoM21 P1 M22 Release SD card M23 [filename. extrusion temperature 160. My pause button in webcontrol stopped working - it's ghosted with a stop-sign courser when I hover it. Business, Economics, and Finance. 00°C/sec. g. 4. gco M24 Start/resume SD print M25 Pause SD print M26 [S(Bytes(s)/Pnn] Set SD position. PROMEGA I have installed a BL Touch clone and it works with the direct commands. So please send T0 and M302 P1 and then see if you can send G1 E1 F100 to make. 2nd print: 10seconds permanent skipping at 10x30 at layer 18mm. This document describes the commands that Klipper supports. In that case we must change the motor direction once again M569 P3 S1 ; physical drive 3 goes forwards Change S1 to S0@gixxerfast said in BL Touch not working: Which version of RRF are you using, ver 2? I can't see that you've mentioned it. g ; set bed and extruder max temperatures; --- SECTION: FANS ( ) ---M106 P0 S0 I0 F4 H-1 L0. the 0, 1,2 drivers still work fine. extrusion temperature 160. I have a duex5 attached to a Duet Wifi with firmware 2. 0C. Hi there, Doesn't make a diference. Re: Extrude without a Hotend May 04, 2017 11:25PM. To temporarily disable the MIN_TEMP, you need to run the G-code M302 P1 or M302 S0 - M302 on its own does nothing. Using Extruder-Motor by G-Code (after using M302 P1 to enable cold-extrusion) What catches my eyes is that the text "Heater1" etc. 0. M83 ; set extruder to relative mode echo "Start" G1 E60 F150 ; Extrude 60mm at 2. However, a steps/mm value of 5. So I attached a thermistor to the board just to "fool" the board into thinking there was an active heater but then I get temperature errors. ; Configuration file for Duet WiFi (firmware version 2. Macros also allow for naming gcodes with easier to remember names. Unmount the SD card and insert it into the Duet 2 Maestro board and power on.